Scan misses some Cushing’s disease tumors in small pilot study

Only one positive scan was confirmed; findings do not support routine use

Written by Steve Bryson, PhD |

A technician readies a patient to have an MRI scan.

An imaging technique that uses a radioactive tracer to find pituitary tumors causing Cushing’s disease showed limited and inconsistent results in a small pilot study.

Of the 10 adults with newly diagnosed or persistent/recurrent Cushing’s disease, two had positive results on the scan, called 68Ga-pentixafor PET/MRI. Only one result was confirmed by other tests and remission after surgery to remove the tumor. Three other patients had negative scans despite achieving remission after surgery.

“These results do not support routine clinical use of 68Ga-Pentixafor PET/MRI for [tumor] localization,” the researchers concluded. They said the scan may provide additional information in selected patients but needs further study before becoming part of routine diagnostic procedures.

The pilot study, “68Ga-Pentixafor PET/MRI for identifying corticotroph adenomas in Cushing disease: a pilot study,” was published in the journal Pituitary.

Recommended Reading
An illustration shows a scientist working with petri dishes in a lab.

Protein interaction could point to new Cushing’s treatment approach

Researchers test new approach to locating pituitary tumors

Cushing’s disease is caused by a pituitary tumor called a corticotroph adenoma. The tumor releases too much adrenocorticotropic hormone (ACTH). This causes the body to produce too much cortisol, a condition called hypercortisolism. High cortisol levels can lead to diabetes, high blood pressure, obesity, and cardiovascular disease.

The first-line treatment for Cushing’s disease is usually surgery to remove the pituitary tumor, called a transsphenoidal adenomectomy. Surgeons often use MRI scans to pinpoint the tumor’s exact location so it can be removed without damaging surrounding tissue.

Most of these tumors are microadenomas, measuring less than 10 mm (0.4 inches). Many are not visible on standard MRI scans. When MRI fails to find a tumor, patients can undergo inferior petrosal sinus sampling (IPSS). This invasive procedure measures ACTH in veins draining the pituitary gland to confirm the hormone’s source.

“Improved noninvasive methods for detecting and localizing corticotroph adenomas are still needed in cases where pituitary MRI is unable to implicate a suspicious lesion as the potential source of ACTH-dependent hypercortisolemia,” wrote a team led by researchers at the Memorial Sloan Kettering Cancer Center in New York.

To explore another way to locate these tumors, the team tested 68Ga-pentixafor PET/MRI. The technique combines MRI and PET imaging. It uses a radioactive tracer called gallium-68-labeled pentixafor, which binds to CXCR4, a protein found on some tumor cells.

A recent retrospective study from China reported high sensitivity with this imaging method. Sensitivity, which measures how well a test correctly identifies existing tumors, was 87.2%. It increased to 98.7% when the method was combined with contrast-enhanced MRI.

The new pilot study examined how the scan performed in patients whose MRI results were positive, negative, or inconclusive. It also explored its use in newly diagnosed patients and those with persistent or recurrent disease.

Nine women and one man with newly diagnosed or persistent/recurrent Cushing’s disease underwent 68Ga-Pentixafor PET/MRI. Half were newly diagnosed.

Only one positive scan confirmed in small study

Two patients (20%) had scans showing a buildup of the radioactive tracer in a specific area of the pituitary gland. In one patient, the positive scan matched a lesion seen on MRI. An examination of tissue removed during surgery confirmed the tumor, and the patient achieved remission after surgery, meaning hormone tests no longer showed active disease.

The second patient also had a positive scan, but the MRI results were inconclusive, no tumor was confirmed in the removed tissue, and the disease persisted after surgery. An IPSS confirmed that the excess ACTH came from the pituitary gland but did not pinpoint its location within the gland. The team considered this case indeterminate.

Five patients underwent surgery after imaging: four with newly diagnosed disease and one with recurrent disease. Three patients (30% of the total group) had negative scans but achieved remission after surgery. These were considered false-negative results, meaning the scans failed to detect tumors that were present.

The remaining five patients did not have surgery. Four had persistent or recurrent disease and were treated with medication. The fifth was newly diagnosed and chose medication instead of surgery. Because five patients did not undergo surgery, the researchers could not reliably calculate the scan’s sensitivity or specificity.

The researchers also found relatively low levels of tracer uptake in the pituitary lesions. When the images were adjusted to make faint signals easier to see, remaining tracer in nearby blood vessels also became more visible.

“68Ga-Pentixafor PET/MRI showed limited and variable performance for corticotroph adenoma localization,” the researchers concluded. “Although it may provide complementary information in selected patients with MRI-visible or equivocal lesions, further study is needed before it can be incorporated into diagnostic algorithms or considered an alternative to IPSS.”

Leave a comment

Fill in the required fields to post. Your email address will not be published.

Comments are moderated. Once approved, your comment and username will be publicly visible. Please avoid sharing personal health information or other sensitive details.